HVAC Load, Airflow, Refrigeration, and Thermal Comfort Review

Estimate HVAC loads, airflow, psychrometric states, refrigeration conditions, heat-transfer effects, and thermal comfort for an engineering review.

Start here

New to this workflow? Follow the steps in order, starting with the first tool below. Already know what you need? Jump straight to the matching step — every tool in this workflow is listed in the comparison table.

First tool: Cooling Load Calculator (Area / U-value + Infiltration)

Hubs

Tools in this workflow, compared

ToolWhat it doesCategory
Cooling Load Calculator (Area / U-value + Infiltration)Estimate the cooling load of a room by the simplified ASHRAE steady-state method. Transmission sensible load Q_trans = Σ(A_i·U_i·ΔT) over envelope surfaces entered one per line as 'area,U' (U in W/(m²·K)). Infiltration/ventilation sensible Q_s = 1.23·ACH·V·ΔT and latent Q_l = 3010·ACH·V·ΔW (W), where ΔW is the indoor-outdoor humidity-ratio difference derived from dry-bulb temperature and relative humidity via the Magnus saturation fit. Total cooling load = total sensible + total latent. Temperature in °C/K/°F (only differences matter), area in m²/ft².Math & Numbers
Heating Load Calculator (Envelope Transmission + Infiltration)Estimate the heating (heat-loss) load of a room by the simplified steady-state method. Envelope transmission loss Q_trans = Σ(A_i·U_i·ΔT) over surfaces entered one per line as 'area,U' (U in W/(m²·K)). Cold-air infiltration loss Q_inf = 0.018·ACH·V·ΔT (W), where 0.018 W·h/(m³·K) ≈ ρ·c_p/3600. Total load = Q_trans + Q_inf, optionally multiplied by a safety factor (default 1.0). ΔT = indoor - outdoor (heating, >0). Temperature in °C/K/°F (only differences matter), area in m²/ft².Math & Numbers

Hubs

Continue with adjacent topic clusters

Sensible / Latent Heat Split (SHR = Sensible / Total)
Split an air-conditioning load into sensible and latent components. Total cooling capacity Qt = ṁ_da·(h1 − h2); sensible capacity Qs = ṁ_da·cp_ma·(T1 − T2) with cp_ma ≈ 1.006 + 1.86·W [kJ/(kg da·K)]; latent capacity Ql = Qt − Qs; Sensible Heat Ratio SHR = Qs / Qt. Entering/leaving states are described by dry-bulb temperature T and humidity ratio W; enthalpy h = 1.006·T + W·(2501 + 1.86·T) [kJ/kg da]. Three modes: full air-state split (T1,W1)→(T2,W2), from Qt & Qs (solve SHR + Ql), or from Qt & SHR (solve Qs, Ql).
Math & Numbers
AHU Coil Capacity Calculator (Cooling / Heating)Compute the total, sensible, and latent capacity of an air-handling-unit (AHU) coil from the entering/leaving air state and the dry-air mass flow ṁ_da. Total capacity Qt = ṁ_da·(h1 − h2); sensible capacity Qs = ṁ_da·cp_ma·(T1 − T2) with cp_ma ≈ 1.006 + 1.86·W [kJ/(kg da·K)]; latent capacity Ql = Qt − Qs; Sensible Heat Ratio SHR = Qs / Qt. Each state is described by dry-bulb T plus one humidity input (relative humidity φ, or humidity ratio W); W is derived from the Magnus saturation fit when RH is supplied, and enthalpy h = 1.006·T + W·(2501 + 1.86·T) [kJ/kg da]. Signed result — works for cooling or heating coils.Math & Numbers
Ventilation Rate Calculator (People / Area / Contaminant)Compute the required outdoor / supply ventilation rate. ASHRAE 62.1 ventilation-rate procedure: people component Vpz = Rp·P, area component Vaz = Ra·A, breathing-zone outdoor air Vbz = Vpz + Vaz, zone supply airflow Voz = Vbz / Ez. Three modes: ASHRAE 62.1 (people + area), per-person rate (P × Rp), or contaminant dilution (Q = G / (C_acc − C_sup), where G can be mg/s, mg/h, or L/s of gas and concentrations mg/m³ or ppm). Results reported in L/s, m³/h, and CFM.Math & Numbers
Air Changes per Hour (ACH, n = Q/V)Compute the air change rate (ACH / n) of a room from the outdoor supply airflow Q and the room volume V: n = Q/V (1/h). Three modes: solve ACH (given Q and V), solve airflow (given n and V), or solve volume (given n and Q). Flow in m³/s/m³/h/CFM, volume in m³/ft³/L. Also reports the well-mixed single-zone purge time to reach a target residual fraction ε (default 1%): t = −ln(ε)/n hours.Math & Numbers
Volumetric Flow Rate Converter (m³/h / L/min / gpm / cfm)Convert volumetric flow rate between m³/h (cubic metres per hour), L/min (litres per minute), gpm (US gallons per minute, 1 gal = 3.785411784 L), and cfm (cubic feet per minute, 1 ft³ = 28.3168466 L). Converts via m³/s to the target unit and also lists the equivalent value in all four units for reference. Used for pumps, HVAC, compressed air, and piping.Math & Numbers
Duct Size Calculator (Flow Rate × Velocity)Size a duct cross-section from the air flow rate Q and the design mean velocity v: area A = Q/v. Circular duct diameter D = √(4A/π). Rectangular duct with aspect ratio r = a/b gives b = √(A/r) and a = r·b, plus the ASHRAE equivalent diameter D_eq = 1.30·(a·b)^0.625/(a+b)^0.25. Flow rate in m³/s/m³/h/CFM, velocity in m/s; dimensions reported in mm and inches.Math & Numbers
Psychrometric Properties (Humidity Ratio / Enthalpy / RH)Compute the full set of moist-air (psychrometric) state properties from dry-bulb temperature plus one humidity input (relative humidity φ, wet-bulb temperature, dew-point temperature, or humidity ratio W). Returns humidity ratio W (kg/kg and g/kg), relative humidity φ (%), dew-point, wet-bulb, enthalpy h (kJ/kg dry air), specific volume v (m³/kg dry air), partial vapour pressure P_w, and saturation pressure P_ws. Uses the Magnus saturation-pressure fit; wet-bulb is solved iteratively from the thermodynamic psychrometric equation. Default standard atmosphere 101.325 kPa (adjustable). Temperature in °C/K/°F; all reported temperatures are in °C.Math & Numbers
Dew Point Calculator HVAC (Magnus Equation)Compute the air dew-point temperature from dry-bulb temperature and a humidity reading using the Magnus saturation-pressure equation: P_ws(T) = 0.6108·exp(17.27·T/(T+237.3)), P_w = φ·P_ws, T_dp = 237.3·ln(P_w/0.6108) / (17.27 − ln(P_w/0.6108)). Also returns the saturation vapour pressure P_ws, actual partial pressure P_w, and absolute humidity ρ_v (kg/m³). Three input modes: relative humidity φ (natural ventilated), August natural-ventilated wet-bulb T_w, or aspirated (Assmann) wet-bulb T_wa. Temperature in °C/K/°F; all reported temperatures are in the selected Temperature Unit.Math & Numbers
Refrigerant Pressure-Temperature Lookup (R-22 / R-410A / R-134a)Saturated pressure ↔ temperature lookup for common HVAC refrigerants via the Antoine fit ln(P) = A − B/(T_C + C): R-22 (HCFC-22), R-134a (HFC-134a), and R-410A (R-32/R-125 near-azeotropic blend). Coefficients fitted against the ASHRAE Handbook / NIST REFPROP saturation tables. Two modes: solve saturation pressure from temperature, or solve saturation temperature from pressure. Pressure may be absolute or gauge (atmospheric default 1.01325 bar) in bar/MPa/kPa/PSI; temperature in °C/K/°F. Engineering estimate only — does not replace the manufacturer's P-T chart.Math & Numbers
Condensing / Evaporating Temperature CalculatorEstimate the saturated condensing temperature (T_cond) and evaporating temperature (T_evap) of a refrigeration circuit. Three modes: (1) from coil approach — T_cond = T_ambient + condenser ΔT approach, T_evap = T_medium − evaporator ΔT approach; (2) from measured saturated pressures — given P_cond and P_evap for a known refrigerant (R-22 / R-134a / R-410A), invert the Antoine fit; (3) from subcooling & superheat — T_cond = T_liquid − SC, T_evap = T_suction − SH. Temperature in °C/K/°F; pressure in bar/MPa/kPa/PSI absolute or gauge (atmospheric default 1.01325 bar). Results reported in °C.Math & Numbers
COP Calculator (Coefficient of Performance, COP = Q_c / W)Compute the Coefficient of Performance (COP) of a chiller / heat pump: COP = Q_c / W, where Q_c is the cooling capacity and W the work input (both in consistent power units; COP is dimensionless). Three modes: solve COP (given Q_c and W), solve cooling capacity (given COP and W), or solve input power (given COP and Q_c). Capacity in W/kW/BTU·h⁻¹/ton/kcal·h⁻¹, power in W/kW/hp; all converted to W internally.Math & Numbers
EER ↔ SEER ↔ COP Converter (Refrigeration Efficiency)Convert between the three common refrigeration efficiency metrics: COP (dimensionless, W/W), EER (Btu/(W·h)), and SEER (seasonal Btu/(W·h)). Standard relations: COP = EER / 3.412, EER = COP × 3.412, SEER = EER / α (α seasonal weighting factor, default 0.875, adjustable 0.8–0.91 to match regional standards such as ARI 210/240). Enter any one metric and all three are reported.Math & Numbers
Heat Exchanger LMTD Calculator (Log Mean Temperature Difference)Compute the Log Mean Temperature Difference (LMTD) of a heat exchanger for parallel or counter flow. Parallel flow: ΔT₁ = T_h,in - T_c,in and ΔT₂ = T_h,out - T_c,out; counter flow: ΔT₁ = T_h,in - T_c,out and ΔT₂ = T_h,out - T_c,in. LMTD = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂), or ΔT₁ when ΔT₁ = ΔT₂. A non-positive terminal difference (temperature cross) is physically impossible and is rejected. Optionally, with the overall heat transfer coefficient U (W/(m²·K)) and the heat transfer area A (m²), the heat transfer rate Q = U·A·LMTD (W) is returned. Temperatures are used only as differences: Δ°C = ΔK and Δ°F ×5/9 = ΔK; the LMTD is reported in K.Math & Numbers
Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.Math & Numbers
Overall Heat Transfer Coefficient (1/U=ΣR)Compute the overall heat transfer coefficient for series thermal resistances (flat-wall model): total resistance R_total = Σ R_i (K/W), thermal conductance G = 1/R_total (W/K), area-based coefficient U = 1/(R_total·A) (W/(m²·K)), and if a temperature difference is given the heat flow rate Q = ΔT/R_total (W). Each R_i is a layer resistance already containing the area factor (e.g. convection R_conv=1/(h·A), conduction R_cond=d/(k·A), fouling R_foul=R_f''/A). Enter one resistance (K/W) per line, at least one, all positive. ΔT may be negative (reverse heat flow); a °C difference equals a K difference, a °F difference is converted by ×5/9.Math & Numbers
Heat Transfer Coefficient Converter (W/(m²·K) ↔ kcal)Convert convective heat transfer coefficient (film coefficient h) between W/(m²·K) (watt per square metre-kelvin, SI base, = W/(m²·°C)) and kcal/(m²·h·°C) (1 = 1.1627778 W/(m²·K)). Converts via W/(m²·K) and lists both equivalents. h depends on flow regime and surface, not material. Typical ranges: natural-convection air ≈ 5–25, forced air ≈ 25–250, still water ≈ 100–1000, boiling/condensing water ≈ 2500–50000+ W/(m²·K).Math & Numbers
Thermal Conductivity Converter (W/(m·K) / kcal / BTU)Convert thermal conductivity between W/(m·K) (watt per metre-kelvin, SI base, = W/(m·°C)), kcal/(m·h·°C) (1 = 1.1627778 W/(m·K)), and BTU/(hr·ft·°F) (1 = 1.7307347 W/(m·K)). Converts via W/(m·K) to the target unit and also lists the equivalent value in all three units for reference. Reference values: copper ≈ 401, aluminum ≈ 237, steel ≈ 50, water ≈ 0.6, air ≈ 0.026, insulation foam ≈ 0.03 W/(m·K).Math & Numbers
Thermal Comfort PMV-PPD (ISO 7730 / Fanger)Compute the thermal comfort indices PMV (Predicted Mean Vote, −3 cold..+3 hot) and PPD (Predicted Percentage Dissatisfied, %) per ISO 7730 / ASHRAE 55, using the Fanger equations. Inputs: air temperature Ta, mean radiant temperature Tr, relative air velocity v_ar, relative humidity φ, metabolic rate M (met; 1 met = 58.2 W/m²), clothing insulation Icl (clo; 1 clo = 0.155 m²·K/W), and external work W (defaults to 0). The clothing surface temperature Tcl is solved iteratively. Returns a 7-level ASHRAE sensation label.Math & Numbers

Build the review from demand to delivery

A credible HVAC review starts by making the load picture explicit. Estimate cooling and heating separately, then split sensible and latent effects so later airflow and humidity checks are anchored to the same assumptions. If an air-handling unit or packaged system is being screened, keep the available capacity in view instead of treating the room load as the only controlling number.

Translate the load into air and moisture behavior

Once the demand is framed, convert it into ventilation and supply airflow targets. Compare outside-air requirements, room air changes, and duct velocity constraints before assuming the system can actually move the required air. Psychrometric and dew-point checks then show whether the target condition is realistic, whether moisture removal is aligned with the load split, and whether the review is drifting toward condensation or comfort problems.

Separate equipment limits from comfort limits

Refrigeration checks help explain why a system misses a target. Pressure-temperature relationships, condensing conditions, and COP or EER trends can reveal whether the problem sits in the cycle, the airflow path, or the design assumptions. Finish by reviewing heat-transfer terms and PMV under the stated conditions, and state plainly that these calculations support engineering review only; they do not replace qualified design, code compliance, manufacturer selection, or safety review.

Before you start

  • Gather design indoor and outdoor conditions, envelope assumptions, occupancy, and the review scenario before calculating.
  • Define the review objective such as concept comparison, retrofit screening, troubleshooting, or pre-submittal engineering review.

Workflow playbook

HVAC engineering review: load, airflow, psychrometrics, refrigeration, comfort

  1. 1

    Frame the thermal demand

    Estimate the cooling and heating requirement for the space, then separate sensible and latent effects so the review begins with a transparent demand picture instead of a single total number.

  2. 2

    Set ventilation and supply airflow targets

    Translate occupancy and air-change requirements into comparable airflow units, then check whether the proposed duct path and supply strategy can reasonably move that air.

  3. 3

    Review moist-air conditions

    Use psychrometric properties and dew point to check humidity control, coil leaving-air expectations, condensation risk, and whether the proposed load split is consistent with the air state.

  4. 4

    Check the refrigeration cycle and efficiency story

    Cross-check pressure-temperature relationships, condensing conditions, and efficiency metrics so the review can distinguish between a load problem, an airflow problem, and a refrigeration-side limitation.

  5. 5

    Close with heat-transfer and comfort evidence

    Review coil or envelope transfer assumptions, convert heat-transfer terms where needed, and test whether occupant comfort stays reasonable under the stated conditions before issuing the engineering note.

Choose the right path

Should the review start from room load or from installed equipment behavior?

Start from room load for concept design, retrofit scoping, or envelope changes. Start from equipment behavior when the main question is a refrigeration, airflow, or comfort complaint in an existing system.

Is this result suitable for design approval?

Use this workflow for estimation, cross-checking, and engineering discussion. If the outcome affects compliance, safety, final equipment selection, or sealed documents, escalate to qualified design review with site and manufacturer data.

Done when

  • The review packet records load assumptions, sensible and latent split, airflow targets, ventilation basis, and the psychrometric state used for each major conclusion.
  • Refrigeration and heat-transfer checks are consistent with the selected operating conditions, and any comfort conclusion is tied to stated occupancy and environmental assumptions.
  • The final note clearly states that calculations support engineering review only and do not replace qualified design, code compliance, manufacturer selection, or safety review.
Hub

Measurement and Unit Conversion Tools

Convert length, weight, temperature, speed, pressure, energy, force, density, area, volume, angle, and time units from one focused workflow.

Hub

Physics Classroom and Lab Calculators

Compare mechanics, fluid, wave, sound, pressure, and significant-figure tools in one focused educational physics workflow.

Hub

Electrical Circuit Power and Cable Sizing Workflow

Calculate circuit relationships, compare resistor and capacitor formulas, convert power or energy units, and estimate voltage drop before choosing a cable size.

Home
Tools3208
Samples593
Visualizations469
Viewers103
Hubs237
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance646

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web193

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff
Small-Room Furniture Layout Review and Move-In Handoff
FLAC/WAV Source Screening and Evidence Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact

Math & Numbers

Cooling Load Calculator (Area / U-value + Infiltration)

Estimate the cooling load of a room by the simplified ASHRAE steady-state method. Transmission sensible load Q_trans = Σ(A_i·U_i·ΔT) over envelope surfaces entered one per line as 'area,U' (U in W/(m²·K)). Infiltration/ventilation sensible Q_s = 1.23·ACH·V·ΔT and latent Q_l = 3010·ACH·V·ΔW (W), where ΔW is the indoor-outdoor humidity-ratio difference derived from dry-bulb temperature and relative humidity via the Magnus saturation fit. Total cooling load = total sensible + total latent. Temperature in °C/K/°F (only differences matter), area in m²/ft².

Math & Numbers

Heating Load Calculator (Envelope Transmission + Infiltration)

Estimate the heating (heat-loss) load of a room by the simplified steady-state method. Envelope transmission loss Q_trans = Σ(A_i·U_i·ΔT) over surfaces entered one per line as 'area,U' (U in W/(m²·K)). Cold-air infiltration loss Q_inf = 0.018·ACH·V·ΔT (W), where 0.018 W·h/(m³·K) ≈ ρ·c_p/3600. Total load = Q_trans + Q_inf, optionally multiplied by a safety factor (default 1.0). ΔT = indoor - outdoor (heating, >0). Temperature in °C/K/°F (only differences matter), area in m²/ft².

Math & Numbers

Sensible / Latent Heat Split (SHR = Sensible / Total)

Split an air-conditioning load into sensible and latent components. Total cooling capacity Qt = ṁ_da·(h1 − h2); sensible capacity Qs = ṁ_da·cp_ma·(T1 − T2) with cp_ma ≈ 1.006 + 1.86·W [kJ/(kg da·K)]; latent capacity Ql = Qt − Qs; Sensible Heat Ratio SHR = Qs / Qt. Entering/leaving states are described by dry-bulb temperature T and humidity ratio W; enthalpy h = 1.006·T + W·(2501 + 1.86·T) [kJ/kg da]. Three modes: full air-state split (T1,W1)→(T2,W2), from Qt & Qs (solve SHR + Ql), or from Qt & SHR (solve Qs, Ql).

Math & Numbers

AHU Coil Capacity Calculator (Cooling / Heating)

Compute the total, sensible, and latent capacity of an air-handling-unit (AHU) coil from the entering/leaving air state and the dry-air mass flow ṁ_da. Total capacity Qt = ṁ_da·(h1 − h2); sensible capacity Qs = ṁ_da·cp_ma·(T1 − T2) with cp_ma ≈ 1.006 + 1.86·W [kJ/(kg da·K)]; latent capacity Ql = Qt − Qs; Sensible Heat Ratio SHR = Qs / Qt. Each state is described by dry-bulb T plus one humidity input (relative humidity φ, or humidity ratio W); W is derived from the Magnus saturation fit when RH is supplied, and enthalpy h = 1.006·T + W·(2501 + 1.86·T) [kJ/kg da]. Signed result — works for cooling or heating coils.

Math & Numbers

Ventilation Rate Calculator (People / Area / Contaminant)

Compute the required outdoor / supply ventilation rate. ASHRAE 62.1 ventilation-rate procedure: people component Vpz = Rp·P, area component Vaz = Ra·A, breathing-zone outdoor air Vbz = Vpz + Vaz, zone supply airflow Voz = Vbz / Ez. Three modes: ASHRAE 62.1 (people + area), per-person rate (P × Rp), or contaminant dilution (Q = G / (C_acc − C_sup), where G can be mg/s, mg/h, or L/s of gas and concentrations mg/m³ or ppm). Results reported in L/s, m³/h, and CFM.

Math & Numbers

Air Changes per Hour (ACH, n = Q/V)

Compute the air change rate (ACH / n) of a room from the outdoor supply airflow Q and the room volume V: n = Q/V (1/h). Three modes: solve ACH (given Q and V), solve airflow (given n and V), or solve volume (given n and Q). Flow in m³/s/m³/h/CFM, volume in m³/ft³/L. Also reports the well-mixed single-zone purge time to reach a target residual fraction ε (default 1%): t = −ln(ε)/n hours.

Math & Numbers

Volumetric Flow Rate Converter (m³/h / L/min / gpm / cfm)

Convert volumetric flow rate between m³/h (cubic metres per hour), L/min (litres per minute), gpm (US gallons per minute, 1 gal = 3.785411784 L), and cfm (cubic feet per minute, 1 ft³ = 28.3168466 L). Converts via m³/s to the target unit and also lists the equivalent value in all four units for reference. Used for pumps, HVAC, compressed air, and piping.

Math & Numbers

Duct Size Calculator (Flow Rate × Velocity)

Size a duct cross-section from the air flow rate Q and the design mean velocity v: area A = Q/v. Circular duct diameter D = √(4A/π). Rectangular duct with aspect ratio r = a/b gives b = √(A/r) and a = r·b, plus the ASHRAE equivalent diameter D_eq = 1.30·(a·b)^0.625/(a+b)^0.25. Flow rate in m³/s/m³/h/CFM, velocity in m/s; dimensions reported in mm and inches.

Math & Numbers

Psychrometric Properties (Humidity Ratio / Enthalpy / RH)

Compute the full set of moist-air (psychrometric) state properties from dry-bulb temperature plus one humidity input (relative humidity φ, wet-bulb temperature, dew-point temperature, or humidity ratio W). Returns humidity ratio W (kg/kg and g/kg), relative humidity φ (%), dew-point, wet-bulb, enthalpy h (kJ/kg dry air), specific volume v (m³/kg dry air), partial vapour pressure P_w, and saturation pressure P_ws. Uses the Magnus saturation-pressure fit; wet-bulb is solved iteratively from the thermodynamic psychrometric equation. Default standard atmosphere 101.325 kPa (adjustable). Temperature in °C/K/°F; all reported temperatures are in °C.

Math & Numbers

Dew Point Calculator HVAC (Magnus Equation)

Compute the air dew-point temperature from dry-bulb temperature and a humidity reading using the Magnus saturation-pressure equation: P_ws(T) = 0.6108·exp(17.27·T/(T+237.3)), P_w = φ·P_ws, T_dp = 237.3·ln(P_w/0.6108) / (17.27 − ln(P_w/0.6108)). Also returns the saturation vapour pressure P_ws, actual partial pressure P_w, and absolute humidity ρ_v (kg/m³). Three input modes: relative humidity φ (natural ventilated), August natural-ventilated wet-bulb T_w, or aspirated (Assmann) wet-bulb T_wa. Temperature in °C/K/°F; all reported temperatures are in the selected Temperature Unit.

Math & Numbers

Refrigerant Pressure-Temperature Lookup (R-22 / R-410A / R-134a)

Saturated pressure ↔ temperature lookup for common HVAC refrigerants via the Antoine fit ln(P) = A − B/(T_C + C): R-22 (HCFC-22), R-134a (HFC-134a), and R-410A (R-32/R-125 near-azeotropic blend). Coefficients fitted against the ASHRAE Handbook / NIST REFPROP saturation tables. Two modes: solve saturation pressure from temperature, or solve saturation temperature from pressure. Pressure may be absolute or gauge (atmospheric default 1.01325 bar) in bar/MPa/kPa/PSI; temperature in °C/K/°F. Engineering estimate only — does not replace the manufacturer's P-T chart.

Math & Numbers

Condensing / Evaporating Temperature Calculator

Estimate the saturated condensing temperature (T_cond) and evaporating temperature (T_evap) of a refrigeration circuit. Three modes: (1) from coil approach — T_cond = T_ambient + condenser ΔT approach, T_evap = T_medium − evaporator ΔT approach; (2) from measured saturated pressures — given P_cond and P_evap for a known refrigerant (R-22 / R-134a / R-410A), invert the Antoine fit; (3) from subcooling & superheat — T_cond = T_liquid − SC, T_evap = T_suction − SH. Temperature in °C/K/°F; pressure in bar/MPa/kPa/PSI absolute or gauge (atmospheric default 1.01325 bar). Results reported in °C.

Math & Numbers

COP Calculator (Coefficient of Performance, COP = Q_c / W)

Compute the Coefficient of Performance (COP) of a chiller / heat pump: COP = Q_c / W, where Q_c is the cooling capacity and W the work input (both in consistent power units; COP is dimensionless). Three modes: solve COP (given Q_c and W), solve cooling capacity (given COP and W), or solve input power (given COP and Q_c). Capacity in W/kW/BTU·h⁻¹/ton/kcal·h⁻¹, power in W/kW/hp; all converted to W internally.

Math & Numbers

EER ↔ SEER ↔ COP Converter (Refrigeration Efficiency)

Convert between the three common refrigeration efficiency metrics: COP (dimensionless, W/W), EER (Btu/(W·h)), and SEER (seasonal Btu/(W·h)). Standard relations: COP = EER / 3.412, EER = COP × 3.412, SEER = EER / α (α seasonal weighting factor, default 0.875, adjustable 0.8–0.91 to match regional standards such as ARI 210/240). Enter any one metric and all three are reported.

Math & Numbers

Heat Exchanger LMTD Calculator (Log Mean Temperature Difference)

Compute the Log Mean Temperature Difference (LMTD) of a heat exchanger for parallel or counter flow. Parallel flow: ΔT₁ = T_h,in - T_c,in and ΔT₂ = T_h,out - T_c,out; counter flow: ΔT₁ = T_h,in - T_c,out and ΔT₂ = T_h,out - T_c,in. LMTD = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂), or ΔT₁ when ΔT₁ = ΔT₂. A non-positive terminal difference (temperature cross) is physically impossible and is rejected. Optionally, with the overall heat transfer coefficient U (W/(m²·K)) and the heat transfer area A (m²), the heat transfer rate Q = U·A·LMTD (W) is returned. Temperatures are used only as differences: Δ°C = ΔK and Δ°F ×5/9 = ΔK; the LMTD is reported in K.

Math & Numbers

Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)

Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.

Math & Numbers

Overall Heat Transfer Coefficient (1/U=ΣR)

Compute the overall heat transfer coefficient for series thermal resistances (flat-wall model): total resistance R_total = Σ R_i (K/W), thermal conductance G = 1/R_total (W/K), area-based coefficient U = 1/(R_total·A) (W/(m²·K)), and if a temperature difference is given the heat flow rate Q = ΔT/R_total (W). Each R_i is a layer resistance already containing the area factor (e.g. convection R_conv=1/(h·A), conduction R_cond=d/(k·A), fouling R_foul=R_f''/A). Enter one resistance (K/W) per line, at least one, all positive. ΔT may be negative (reverse heat flow); a °C difference equals a K difference, a °F difference is converted by ×5/9.

Math & Numbers

Heat Transfer Coefficient Converter (W/(m²·K) ↔ kcal)

Convert convective heat transfer coefficient (film coefficient h) between W/(m²·K) (watt per square metre-kelvin, SI base, = W/(m²·°C)) and kcal/(m²·h·°C) (1 = 1.1627778 W/(m²·K)). Converts via W/(m²·K) and lists both equivalents. h depends on flow regime and surface, not material. Typical ranges: natural-convection air ≈ 5–25, forced air ≈ 25–250, still water ≈ 100–1000, boiling/condensing water ≈ 2500–50000+ W/(m²·K).

Math & Numbers

Thermal Conductivity Converter (W/(m·K) / kcal / BTU)

Convert thermal conductivity between W/(m·K) (watt per metre-kelvin, SI base, = W/(m·°C)), kcal/(m·h·°C) (1 = 1.1627778 W/(m·K)), and BTU/(hr·ft·°F) (1 = 1.7307347 W/(m·K)). Converts via W/(m·K) to the target unit and also lists the equivalent value in all three units for reference. Reference values: copper ≈ 401, aluminum ≈ 237, steel ≈ 50, water ≈ 0.6, air ≈ 0.026, insulation foam ≈ 0.03 W/(m·K).

Math & Numbers

Thermal Comfort PMV-PPD (ISO 7730 / Fanger)

Compute the thermal comfort indices PMV (Predicted Mean Vote, −3 cold..+3 hot) and PPD (Predicted Percentage Dissatisfied, %) per ISO 7730 / ASHRAE 55, using the Fanger equations. Inputs: air temperature Ta, mean radiant temperature Tr, relative air velocity v_ar, relative humidity φ, metabolic rate M (met; 1 met = 58.2 W/m²), clothing insulation Icl (clo; 1 clo = 0.155 m²·K/W), and external work W (defaults to 0). The clothing surface temperature Tcl is solved iteratively. Returns a 7-level ASHRAE sensation label.