Electrical Engineering Tools Online
Browse 14 online electrical engineering tools for processing, converting, validating, and managing related files and data.
Explore 14 electrical engineering tools for working with related files and data through a browser-based interface, with no software installation required.
Tools
14 matching tools
Math & Numbers
RLC Admittance Calculator (Y = G + jB)
Compute complex admittance Y = 1/Z = G + jB for series or parallel RLC circuits: G = R/|Z|², B = −X/|Z|². Returns conductance, susceptance, magnitude and phase angle. Supports any subset of R/L/C.
Math & Numbers
Cable Ampacity Calculator (IEC 60364-5-52)
Estimate copper cable current-carrying capacity per the simplified IEC 60364-5-52 reference method. Combines cross-section, insulation (PVC 70°C / XLPE 90°C), installation method, and ambient temperature to derive the corrected allowable ampacity (A).
Math & Numbers
Capacitor Reactive Power Calculator (Q_c = 2πfCU²)
Compute the reactive power produced by a known capacitor: Q_c = 2π·f·C·U². Supports single-phase, three-phase star (Y) and delta (Δ) connections. Returns Q_c in var/kvar, capacitive reactance Xc, and capacitor current Ic. Complementary to the power-factor-correction tool (which sizes a capacitor for a target cosφ).
Math & Numbers
RLC Impedance & Phase Angle Calculator
Compute complex impedance, magnitude |Z| and phase angle φ for series or parallel RLC circuits: X_L=2πfL, X_C=1/(2πfC), |Z|=√(R²+X²), φ=atan2(X,R). Supports any subset of R/L/C and an optional linear frequency sweep.
Math & Numbers
Motor Efficiency Calculator (η = P_out / P_in)
Compute motor efficiency η = P_out / P_in. Supports electrical input (single-phase U·I·cosφ or three-phase √3·U·I·cosφ) or direct P_in; output power can be derived from a loss breakdown (copper+iron+rotor copper+mechanical+stray) or supplied directly.
Math & Numbers
Three-Phase Induction Motor Slip Calculator
Compute three-phase induction motor slip: synchronous speed n_s = 60·f/p and slip s = (n_s − n)/n_s. Supports slip-from-speed and speed-from-slip modes; automatically flags generator mode (s < 0).
Math & Numbers
Induction Motor Torque-Speed Characteristic (Kloss)
Build the torque-speed curve of a three-phase induction motor using the Kloss equation T/T_max = 2/(s/s_max + s_max/s). Returns rated torque, breakdown (max) torque, starting torque, breakdown slip, and a sampled T-n curve with configurable point count.
Math & Numbers
Power Factor Correction Calculator
Size the shunt capacitor needed to raise the power factor: C = P·(tanφ₁ − tanφ₂)/(2π·f·U²). Returns compensated reactive power Qc, capacitive reactance Xc, capacitor current Ic, and the required capacitance in F/μF.
Math & Numbers
Inverse-Time Overcurrent Relay Setting (IEC 60255-151)
Compute the operating time of an inverse-time overcurrent relay per IEC 60255-151: t = TMS·(k/((I/I_s)^α − 1)). Supports Standard Inverse (SI), Very Inverse (VI), Extremely Inverse (EI) and Long-Time Inverse (LTI) curves, and samples a T-I characteristic.
Math & Numbers
Three-Phase Short-Circuit Current Calculator (IEC 60909)
Estimate the three-phase symmetric short-circuit current using the IEC 60909 far-from-generator method: I"_k = c·U_n/(√3·|Z|) and i_p = κ·√2·I"_k with κ = 1.02 + 0.98·e^(−3R/X). Source impedance is the series sum of transformer and line R/X.
Math & Numbers
Three-Phase Power Calculator
Calculate active, reactive, and apparent power for a balanced three-phase system: S=√3·U·I, P=√3·U·I·cosφ, Q=√3·U·I·sinφ. Also returns the power-factor angle φ and verifies the power triangle.
Math & Numbers
Transformer Impedance Transfer Calculator
Reflect an impedance through an ideal transformer: Z' = a²·Z, where a = N₁/N₂. Supports secondary→primary and primary→secondary directions; a can be given directly or derived from N₁/N₂. Also returns admittance Y and reflected admittance.
Math & Numbers
Transformer Turns Ratio Calculator
Ideal transformer ratio: a = N₁/N₂ = V₁/V₂ = I₂/I₁. Given turns, voltage, or current on either side, compute a and the corresponding voltage/current on the other side; verifies V₁·I₁ = V₂·I₂.
Math & Numbers
Voltage Regulation Calculator (ΔU%)
Compute transformer or feeder voltage regulation from equivalent-circuit parameters: ΔU% ≈ (I·R·cosφ ± I·X·sinφ)/U·100. Returns both the approximate (linear) and exact (phasor) values; supports lagging, unity and leading power factor.
Tags
Related Tags
Math
502 toolsBrowse 502 online math tools for working with math operations, data, and files in your browser. Text inputs are not stored, and uploaded files are deleted after 6 hours.
Power
36 toolsBrowse 36 online Power tools for working with power-related formats and operations in your browser. Text inputs are not stored, and uploaded files are deleted after 6 hours.
Ratio
55 toolsBrowse 55 online Ratio tools for working with ratios through your browser. Text inputs are not stored, and uploaded files are automatically deleted after 6 hours.
Angle
28 toolsBrowse 28 online angle tools for working with angle data and operations. Use them in your browser with server-side processing.
Size
88 toolsBrowse 88 online Size tools for working with size-related formats and operations. Use them in your browser with server-side processing.
Speed
53 toolsBrowse 53 online speed tools for processing, converting, validating, and managing speed data. Use them in your browser with server-side processing.
Tool usage guide
FAQ
What can I do with these Electrical Engineering tools?
You can process, convert, validate, and manage electrical engineering files and data using the tools in this category.
Do I need to install software?
No software installation is required. You can operate the tools through the browser interface.
How is my data handled?
Your requests are processed on Elysia Tools servers. Text inputs are not stored, and uploaded files are automatically deleted after 6 hours.