1. Non-Entrained Concrete Mix Design
Structural EngineerBackground
A structural engineer needs to design a standard non-entrained concrete mix for an indoor foundation slab requiring a slump of 75-100 mm and a maximum aggregate size of 19 mm.
Problem
Calculate the exact mass of cement, water, sand, and coarse aggregate per cubic meter for a target w/c ratio of 0.45.
How to use
Select a slump of 75-100 mm, maximum aggregate size of 19 mm, and non-entrained air. Enter 0.45 for the water-cement ratio, 2.70 for the sand fineness modulus, and 1600 kg/m³ for the coarse aggregate dry-rodded density.
slump: 75-100, maxSize: 19, air: non-entrained, wcRatio: 0.45, finenessModulus: 2.7, caDensity: 1600Outcome
The tool outputs a mix design requiring 455.56 kg of cement, 205 kg of water, 1008 kg of coarse aggregate, and 662.50 kg of sand per cubic meter, with a mass ratio of 1 : 0.45 : 1.45 : 2.21.