1. Find the cadmium triplet
How to use
Select Cd triplet. Then move the view from perpendicular to along B without moving the field slider.
Outcome
The center π line fades out while the two σ wavelengths stay fixed.
Elysia Tools
Navigation
Physics
Change the magnetic field and viewing angle to compare the Zeeman spectra of cadmium, mercury and sodium, then trace each line to its transition and polarization.
Open static visualizationAt a Glance

Verified Results
Every parameter set and result below is a fixed output of this page's built-in model (each asserted before delivery) and reproduces directly: set the Parameters column in the interactive panel.
| Scenario | Parameters | Result |
|---|---|---|
| Cadmium at zero field | B = 0 T; θ = 90° | 1 coincident, unpolarized line |
| Transverse Cd triplet | B = 1 T; θ = 90° | 3 lines; |Δνσ| = 13.996 GHz; relative weights 1:2:1 |
| Cadmium along B | B = 1 T; θ = 0° | 2 circular σ lines; π is dark |
| Mercury splitting | B = 1 T; θ = 90° | 9 line positions; spacing 6.998 GHz |
| Sodium doublet at zero field | B = 0 T; θ = 90° | 2 lines; Δν = 515.520 GHz |
| Sodium at high field | B = 10 T; θ = 90° | D₁ π (M = +½): deviation of −7.640 GHz from the weak-field prediction |
Sources
Papers and datasets underlying this visualization - every formula, algorithm, and data anchor on the page traces back to the sources below.
National Institute of Standards and Technology. Persistent Lines of Neutral Cadmium (Cd I). NIST Handbook of Basic Atomic Spectroscopic Data.
National Institute of Standards and Technology. Persistent Lines of Neutral Mercury (Hg I). NIST Handbook of Basic Atomic Spectroscopic Data.
CODATA (2022). Bohr magneton in Hz/T. NIST Reference on Constants, Units, and Uncertainty.
Related
Next
Steck D. A.. Sodium D Line Data. Alkali D Line Data.
Deen C. P. (2013). Modification of the MOOG Spectral Synthesis Codes to Account for Zeeman Broadening of Spectral Lines. The Astronomical Journal 146(3), 51.
Sennhauser C., Berdyugina S. V. (2010). Zeeman component decomposition for recovering common profiles and magnetic fields. Astronomy & Astrophysics 522, A57.
Banasek J. T., Engelbrecht S., Pikuz S. A., Shelkovenko T. A., Hammer D. A. (2016). Measuring 10-20 T magnetic fields in single wire explosions using Zeeman splitting. Review of Scientific Instruments 87(10), 103506.
Tool usage guide
A magnetic field splits atomic energy levels, but the observed spectrum depends on which transitions reach the detector. Compare the normal cadmium triplet with the mercury multiplet, then use sodium to see when the weak-field prediction begins to miss the line positions.
Each stick is one photon frequency, with weights added for transitions that coincide. In weak fields, the shift is the difference between the upper and lower g·m values times μB B/h. The sodium model mixes the two excited fine-structure levels and draws the first-order prediction as a separate set of dashed marks.
Rotation of the detector changes the strength and polarization of each visible component, not its photon energy. Along the field, π vanishes and σ+ and σ− rotate in opposite senses. Across the field, π and σ are linear and their electric fields are perpendicular.
Zero magnetic field
Cd and Hg each recover one line. Na still shows D₁ and D₂ because their fine structure exists at B = 0.
Air and vacuum wavelengths
The Cd and Hg preset names use their customary air wavelengths. Values on the plot are in vacuum.
Relative intensity
Equal upper-sublevel populations and optically thin emission are assumed. The sticks do not model hyperfine structure, isotope shifts or real linewidths.
How to use
Select Cd triplet. Then move the view from perpendicular to along B without moving the field slider.
Outcome
The center π line fades out while the two σ wavelengths stay fixed.
How to use
Select Hg components and choose two π lines in succession.
Outcome
They share a polarization direction but correspond to different magnetic sublevels.
How to use
Select Na at high field. Compare the highlighted D₁ π stick with its dashed position and read the displayed frequency difference.
Outcome
The mixed-state transition is shifted from its linear Landé prediction.
No. The anomalous label refers to the different angular momenta and Landé factors, not to a requirement for uneven spacing. The ideal Hg example is equally spaced in frequency.