1. On-axis spherical aberration
How to use
Comparison experiments: On-axis spherical aberration.
Outcome
Start on axis: the symmetric spot and curved ray fans reveal spherical aberration. The RMS curve uses a fixed image plane.
Elysia Tools
Navigation
Physics
Trace spherical lenses surface by surface and link ray fans, spot diagrams and an aperture sweep to separate spherical aberration, coma, astigmatism, field curvature and distortion.
Open static visualizationAt a Glance

Verified Results
Every parameter set and result below is a fixed output of this page's built-in model (each asserted before delivery) and reproduces directly: set the Parameters column in the interactive panel.
| Scenario | Parameters | Result |
|---|---|---|
| On-axis spherical aberration | a = 5 mm; H = 0°; Δz = 0 mm; zₛ = -1 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = -125.772 µm |
| Stop down | a = 2 mm; H = 0°; Δz = 0 mm; zₛ = -1 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = -7.753 µm |
| Off-axis coma | a = 5 mm; H = 10°; Δz = 0 mm; zₛ = -1 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = -186.584 µm |
| Move the image plane | a = 5 mm; H = 10°; Δz = -1.5 mm; zₛ = -1 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = 8.689 µm |
| Move the stop forward | a = 3 mm; H = 10°; Δz = 0 mm; zₛ = -10 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = -105.000 µm |
| Compare the doublet | a = 5 mm; H = 0°; Δz = 0 mm; zₛ = -1 mm; q = 0; λ = 587.6 nm | Δy(+a) − Δy(0) = -9.940 µm |
Sources
Papers and datasets underlying this visualization - every formula, algorithm, and data anchor on the page traces back to the sources below.
Edmund Optics. Comparison of Optical Aberrations.
Edmund Optics. 12.5mm Dia. x 40mm FL, VIS-NIR Coated, Achromatic Lens.
SCHOTT. Optical Glass Datasheet N-BK7.
Related
Next
SCHOTT. Optical Glass Datasheet N-SF5.
Florida State University, Molecular Expressions. Aberrations.
Chen H., Ansys. Why is the RMS spot size listed in Spot Diagram different than the values reported by RSCE and RSRE operands?.
Tool usage guide
In the third-order approximation, transverse spherical aberration scales with pupil height cubed; coma scales with field times pupil height squared. Stopping down reduces both, but does not remove every aberration.
Intercepts relative to the chief ray; normalized pupil horizontally, transverse error in µm vertically. Clipped rays leave gaps.
Each spherical surface is intersected and refracted with Snell’s law; both axes are in mm. The dashed line is the d-line paraxial focal plane.
Origin at the spot centroid, in µm; the dashed circle is the geometric RMS radius. Equal-axis auto scaling; not a diffraction PSF.
The image plane, field and other settings stay fixed during the sweep. No refocusing at each radius; clipping is not aberration correction.
Each field minimizes intercept variance in the two directions separately; zero is the d-line paraxial plane. Focus splitting indicates astigmatism; shared bending indicates field curvature.
This is a geometric model of an object at infinity with uniform pupil sampling. It omits diffraction, coatings, Fresnel losses, polarization, manufacturing errors and finite cement thickness. The doublet primarily corrects on-axis spherical and chromatic aberrations, not all five aberrations. Changing wavelength keeps the reference image plane at the d-line focus.
Clipped pupil
The image plane, field and other settings stay fixed during the sweep. No refocusing at each radius; clipping is not aberration correction.
Best focus is available only within the −4 to +4 mm control range.
This is a geometric model of an object at infinity with uniform pupil sampling. It omits diffraction, coatings, Fresnel losses, polarization, manufacturing errors and finite cement thickness. The doublet primarily corrects on-axis spherical and chromatic aberrations, not all five aberrations. Changing wavelength keeps the reference image plane at the d-line focus.
Image-plane spot diagram
Origin at the spot centroid, in µm; the dashed circle is the geometric RMS radius. Equal-axis auto scaling; not a diffraction PSF.
How to use
Comparison experiments: On-axis spherical aberration.
Outcome
Start on axis: the symmetric spot and curved ray fans reveal spherical aberration. The RMS curve uses a fixed image plane.
How to use
Comparison experiments: Off-axis coma.
Outcome
An off-axis bundle makes an asymmetric spot. Stopping down also reduces coma; it is not immune to aperture changes.
How to use
Comparison experiments: Compare the doublet.
Outcome
The fixed manufacturer prescription is optimized on axis. Change between F, d and C lines to examine residual color focus without moving the reference plane.
In the third-order approximation, transverse spherical aberration scales with pupil height cubed; coma scales with field times pupil height squared. Stopping down reduces both, but does not remove every aberration.