Elysia Tools

Browse tools, examples, visual explainers, and topic guides from one clear workspace.

Top Categories

Hubs

Language
ZHESPTRUFRDEEN

Elysia Tools

Navigation

Media

THD Analyzer

· Last updated:2026-10-23

Measure single-tone harmonic distortion per channel and download a ZIP report.

Details

What this tool helps you do

Use a stationary sine test, not music or a sweep. Analyze 0.05–5 seconds with at least 20 cycles. Frequency refinement is limited to ±1%; at least 80% fundamental energy is required. Hann projections measure harmonic amplitudes below a guarded Nyquist limit. Noise at harmonic frequencies biases results; this is not THD+N. THD dBr is relative to the fundamental; dBFS is relative to digital full scale. A half-window phase/amplitude consistency screen returns inconclusive THD for detected contamination. It cannot resolve arbitrarily close interfering tones.

Execution

Run this tool

Fill in the form, run the tool, and review the result in one place.

Samples

Examples that match this tool

Related

Continue with connected tools and hubs

Written by the Elysia Tools team

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
file, number
Output type
file
Sample coverage
4
API ready
Yes

Overview

The THD Analyzer evaluates single-tone total harmonic distortion per channel from stationary sine wave audio recordings and compiles the results into a downloadable ZIP report.

When to use

  • Measuring harmonic distortion in stationary sine wave recordings from audio hardware or plugins.
  • Quantifying individual harmonic levels and fundamental tone purity across audio channels.
  • Generating multi-channel distortion reports and discrete harmonic metrics from test recordings.

How it works

  1. 1Upload a supported audio file (WAV, FLAC, MP3, AIFF, OGG, or M4A) and define the nominal frequency, analysis window, start offset, and maximum harmonic order.
  2. 2The tool isolates the specified segment, requiring at least 20 complete cycles, refines the fundamental frequency within ±1%, and verifies that the fundamental contains at least 80% of total signal energy.
  3. 3Amplitudes for harmonics up to the specified order are computed via Hann window projections below a guarded Nyquist threshold, accompanied by half-window phase and amplitude consistency checks.
  4. 4Results are calculated per channel in dBr relative to the fundamental and in dBFS relative to full scale, then exported in a downloadable ZIP report.

Use cases

  • Evaluating line output fidelity and harmonic distortion on audio interfaces using a 1 kHz test sine wave.
  • Measuring odd and even harmonic coloration produced by analog outboard preamps or tape emulation software.
  • Verifying that audio signal generators produce clean test tones with distortion within target tolerances.

Examples

1. Hardware Interface 1 kHz Sine Tone Audit

Audio QA Engineer

Background

A quality assurance engineer needs to verify the total harmonic distortion of a production run audio interface output using a recorded 1 kHz loopback tone.

Problem

Calculate individual harmonic levels and channel THD without manual spectral analysis calculations.

How to use

Upload the 1 kHz loopback WAV file, set Nominal Frequency to 1000 Hz, specify a 1-second analysis window starting at 0.5 seconds, and set Harmonic Order to 10.

Nominal frequency: 1000 Hz, Start: 0.5 s, Window: 1.0 s, Harmonic order: 10

Outcome

Downloads a ZIP report detailing per-channel THD in dBr and dBFS alongside individual harmonic amplitudes from H2 to H10.

2. Low-Frequency Sine Purity Verification

Sound Lab Technician

Background

A lab technician records a 100 Hz calibration tone generated by an analog bench signal generator.

Problem

Confirm whether low-frequency harmonic distortion remains low enough for calibration use before running acoustic tests.

How to use

FAQ

Can I analyze music or frequency sweep files?

No. The analyzer requires a stationary single-tone sine wave and will fail or yield inconclusive results on dynamic audio or sweeps.

What is the difference between dBr and dBFS in the results?

dBr measures harmonic distortion relative to the fundamental tone amplitude, while dBFS measures distortion levels relative to digital full scale.

Why does the tool return an inconclusive THD measurement?

A result is marked inconclusive if the fundamental contains less than 80% of the window energy or if half-window consistency checks detect signal instability or interference.

Does this tool calculate THD+N?

No. The tool measures discrete harmonic peak projections (THD) and does not calculate total noise and distortion across the full audio spectrum.

What are the duration limits for the analysis window?

The analysis window must be between 0.05 and 5 seconds and long enough to contain at least 20 full cycles of the test tone.

Hub

Audio Processing Regression Tests: Null, Distortion and Report Handoff

Compare a fixed audio reference with separately processed outputs, document null-test coverage and suitable single-tone THD results, and deliver a reviewed regression record with files and hashes.

Home
Tools3215
Samples593
Visualizations472
Viewers103
Hubs239
Tags333
Images, Audio & Video657

Image, audio, and video processing, conversion, and optimization tools

Math, Date & Finance647

Calculators, numerics, date logic, statistics, and finance tools

Design & Color298

Color, layout, graphics, visual styling, and design helper tools

Text & Writing209

Writing, cleanup, formatting, extraction, and text analysis tools

Developer & Web194

Developer utilities, networking, web debugging, and automation helpers

Conversion & Encoding175

Format, file, archive, unit, and encoding conversion tools

Lead Generation Quiz Launch and Contact Handoff
Memorial Drafts: Family Review and Print Handoff
Private Habit Records: Backup, Restore and Sharing Review
Article to X and LinkedIn Drafts: Fact Review and Handoff
Markdown Interactive Deck Review and Offline Handoff

© 2026 Elysia Tools. All rights reserved.

DocsPricingAboutTerms of ServicePrivacy PolicyCookiesContact
Media

Copyright-Free FLAC Audio Samples

Lossless FLAC audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free MP3 Audio Samples

Collection of royalty-free audio samples for testing and development purposes including nature sounds, meditation music, and ambient audio

Media

Copyright-Free WAV Audio Samples

Uncompressed PCM WAV audio samples for testing and development, mirrored from MP3 set with nature sounds and meditation music

Media

Copyright-Free Raw PCM Audio Samples

Raw PCM s16le audio samples featuring nature ambience and relaxing music for waveform, playback, and conversion workflows

Media

Bit Depth Analyzer

Inspect container precision and per-channel integer low-bit occupancy; download an offline ZIP report.

Media

Audio Chord Progression Detector

Estimate an audio file's chord sequence locally and download CSV, JSON, SVG, and method notes in one ZIP.

Media

Audio SNR Estimator

Estimate per-channel signal-to-noise ratio from separate program and noise-only regions, with an offline ZIP report.

Media

Audio Melody Contour Extractor

Extract a dominant melody path from audio and export MIDI, note events, a pitch contour, SVG, and JSON in one ZIP.

Upload the test file, set Nominal Frequency to 100 Hz, specify a 2-second window to ensure at least 20 cycles, and set the maximum harmonic order to 8.

Nominal frequency: 100 Hz, Start: 0.0 s, Window: 2.0 s, Harmonic order: 8

Outcome

Receives a complete report confirming fundamental lock, phase consistency, and calculated harmonic distortion.