Start using

Normalization History Card

Read more

Generate a shareable before/after report card for any loudness change: gain applied, LUFS, true peak, sample peak, loudness range, waveforms and third-octave spectral deltas.

Inputs

Current media limits

Current plan: —

audio
—
Checking your current limits

Result

Ready for a run

Run the tool to preview files, text, structured data, or streamed output here.

Examples

2 examples

Choose an example to fill in the form.

  • A sine-based master measured at -20.0 LUFS and its loudness-normalized successor at -14.0 LUFS: the card records +6.0 LU of gain, a matching +6.0 dB true-peak delta, an unchanged loudness range and near-identical band spectra — the signature of a pure gain move, graded faithful-gain.

    HTML card: verdict faithful-gain, before -20.0 LUFS / after -14.0 LUFS, gain +6.0 LU, waveform pair and band-delta chart

  • The same -20 LUFS master pushed with +24 dB of raw gain peaks above 0 dBFS: the card flags the result as clipping-risk, shows the true peak crossing full scale and the waveform crests slamming into the shared scale ceiling.

    HTML card: verdict clipping-risk, true peak above 0 dBTP, crests clipped against the waveform scale

Last updated

Details

What this tool helps you do

A readable audit of what normalization did to your audio. Upload the file from before the change and the file from after it — a master before and after loudness normalization, a podcast pass before and after leveling, or any two stages of a chain — and the card measures both with a BS.1770-4 compliant meter, then lays the numbers side by side: integrated loudness, oversampled true peak, sample peak, loudness range (LRA) and duration, with the applied gain computed from the loudness delta. The waveform pair is drawn from the decoded PCM on a shared amplitude scale, so a level change or a squashed crest is visible at a glance, and a third-octave spectral comparison (long-term average spectra of both sides) shows which frequency regions gained or lost energy — a tip-off that more than pure gain was applied. The card ends with a verdict: faithful-gain when the change is a clean level move (loudness delta matches the peak delta and the loudness range survives), dynamics-compressed when LRA shrank by 3 LU or more, clipping-risk when the result peaks above 0 dBTP or 0 dBFS, and level-lowered / level-raised for plain downward or upward moves. Great for documenting delivery versions, proving a normalize pass behaved, or sharing an A/B with a client.

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
File, Text
Output type
html
Sample coverage
4
API ready
Yes

Overview

Generate a comprehensive, shareable HTML before-and-after audit card comparing audio files across loudness changes. Measure BS.1770-4 integrated loudness, true peak, sample peak, loudness range, side-by-side waveforms, and third-octave spectral deltas to verify gain moves, dynamics alterations, and clipping risks.

When to use

  • Verifying that a loudness normalization pass applied pure linear gain without unintended dynamic compression or inter-sample clipping.
  • Auditing podcast leveling passes to verify voice consistency, dynamic range reduction, and loudness standard compliance.
  • Delivering client-facing A/B mastering proof cards showing exact LUFS adjustments, peak headroom, and spectral balance differences.

How it works

  1. 1Upload the original audio file and the post-normalization audio file.
  2. 2Optionally enter a custom card title to label your delivery version or production stage.
  3. 3The tool decodes PCM audio and analyzes both files using an ITU-R BS.1770-4 meter to compute integrated LUFS, oversampled true peak, sample peak, and loudness range (LRA).
  4. 4An HTML report card is generated featuring side-by-side metric tables, shared-scale waveforms, third-octave spectral deltas, and an automated behavioral verdict.

Use cases

  • Auditing post-production loudness passes against target broadcast delivery specifications.
  • Comparing unmastered mixes against mastered deliverables to evaluate dynamic range compression and spectral alterations.
  • Creating documentation for audio batch processing pipelines to guarantee that automated normalization tools do not induce clipping.

Examples

1. Verifying a Streaming Target Normalization

Mastering Engineer

Background

A mastering engineer needs to boost a dynamic acoustic track from -20 LUFS to a target streaming level of -14 LUFS without altering punch or causing inter-sample clipping.

Problem

Confirming that the automated normalization pass applied pure linear gain without unwanted limiting or overshoots.

How to use

Upload the initial pre-normalized master into the original file field, upload the adjusted track into the normalized file field, and set the title to 'Acoustic Master - Streaming Target'.

originalFile: master_orig.wav, normalizedFile: master_norm.wav, cardTitle: 'Acoustic Master - Streaming Target'

Outcome

Receives an HTML card indicating a faithful-gain verdict, showing a +6.0 LU gain delta, matching true peak shift, identical LRA, and flat third-octave differences.

2. Auditing Voice Track Peak Overshoots

Podcast Editor

Background

A podcast producer leveled a raw multi-speaker interview but suspects an aggressive gain multiplier caused distortion across loud speaker laugh peaks.

Problem

Pinpointing whether the normalized dialogue clipped against digital full scale or overshot true peak tolerances.

How to use

Select the unedited podcast mix as the original audio, select the leveled output as the normalized file, and run the audit card generation.

originalFile: episode_raw.wav, normalizedFile: episode_boosted.wav, cardTitle: 'Podcast Loudness Leveling Check'

Outcome

Generates a card showing a clipping-risk verdict, highlighting true peaks above 0 dBTP and waveforms colliding against the shared amplitude scale limit.

FAQ

What audio formats and file sizes are supported?

You can upload standard audio files up to 100 MB each for both the before and after inputs.

How are the loudness metrics measured?

Metrics are analyzed using an ITU-R BS.1770-4 compliant meter to calculate integrated LUFS, oversampled true peak (dBTP), sample peak (dBFS), and loudness range (LRA).

What do the different verdicts indicate?

Verdicts include faithful-gain for clean level shifts, dynamics-compressed when LRA drops by 3 LU or more, clipping-risk if peaks exceed 0 dBTP or 0 dBFS, and level-raised or level-lowered for simple directional moves.

Why does the report include a third-octave spectral delta?

Third-octave spectral analysis compares long-term average spectra across frequency bands to show whether equalization, saturation, or multi-band processing was introduced beyond linear gain.

In what format is the final report provided?

The output is generated as a standalone HTML card that you can view, save, or share directly with collaborators and clients.

Related

Continue with connected tools and hubs

Cookie settings

Essential cookies keep the site running. Analytics and personalized ads are optional.