Start using

Forensic Speech Enhancer

Read more

Speech-focused cleanup for noisy evidence and interview recordings: documented FFmpeg filter chains with presets for evidence clarity, broadcast, telephone band and transcription prep.

Inputs

Current media limits

Current plan: —

audio
—
Checking your current limits

Result

Ready for a run

Run the tool to preview files, text, structured data, or streamed output here.

Examples

2 examples

Choose an example to fill in the form.

  • A speech fixture with four phrases separated by noise-only pauses runs the default evidence-clarity chain at standard strength: the metadata records the exact FFmpeg filter chain, sets the denoiser’s noise floor from the measured pause level, and measures the denoise stage in isolation - the pause noise floor drops by about 9 dB - while the final work product stays true-peak safe under the limiter ceiling.

    Generated file

    Select this example, upload the required file, then run the tool.

  • The same fixture with the transcription-prep preset at strong strength: the chain switches to the heaviest afftdn settings with a noise gate, and the recorded chain string shows the 300-3400 Hz telephone band is NOT applied here - full-band gating instead, built for feeding a speech-to-text pass.

    Generated file

    Select this example, upload the required file, then run the tool.

Last updated

Details

What this tool helps you do

A transparent work-product generator for speech audio that has to be understood, not beautified: noisy evidence recordings, police/procedural interviews, field footage audio. Following the SWGDE technical notes on FFmpeg for forensic audio examination, the tool never touches your original - it renders an enhanced derivative through a documented, reproducible FFmpeg filter chain that is recorded verbatim in the result metadata, so the processing history of the work product can be reported alongside the exhibit. Four chain presets: EVIDENCE CLARITY (the conservative default) keeps the full speech band and applies FFT denoising (afftdn with a chosen reduction and noise floor), de-essing, gentle 2:1 leveling and speech normalization with a true-peak-safe limiter; INTERVIEW BROADCAST adds a 100 Hz-8 kHz wideband speech window with lighter denoising for publishable interview audio; TELEPHONE BAND band-limits to the classic 300-3400 Hz telephony passband - the range classic intelligibility research standardized - plus a noise gate for pauses; TRANSCRIPTION PREP runs the strongest denoise and gating to feed automatic speech recognition, where consistent level matters more than naturalness. Strength (light / standard / strong) scales the denoise amount and noise-floor setting together, so the chain stays balanced. The report measures the input and output with a BS.1770-4 meter (integrated loudness, true peak) and estimates the noise floor before and after from the quietest 10 percent of 100 ms blocks, so the denoise effect is a number, not a claim. Every enhancement is a processing artifact on a copy: keep the original, document the chain, and disclose the enhancement in your work product - this tool makes the disclosure copy-pasteable.

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
File, Select
Output type
File
Sample coverage
4
API ready
Yes

Overview

Forensic Speech Enhancer creates transparent, reproducible audio work products from noisy evidence recordings, field footage, and interviews using documented FFmpeg filter chains. Aligned with SWGDE technical recommendations, it leaves the original file untouched and records the exact command string, BS.1770-4 loudness metrics, and noise floor drop in the output metadata.

When to use

  • Preparing noisy recorded interviews or legal audio exhibits where speech intelligibility must be maximized without altering the source file.
  • Conditioning low-level or background-heavy speech recordings before submitting them to automatic speech recognition (ASR) engines.
  • Documenting chain-of-custody processing history for forensic case reports, disclosures, or broadcast publication copies.

How it works

  1. 1Select an audio file and choose an enhancement preset: Evidence clarity, Interview broadcast, Telephone band, or Transcription prep.
  2. 2Adjust the processing strength to light, standard, or strong, which balances FFT denoising depth and noise floor tracking proportionately.
  3. 3Pick your export container (24-bit PCM WAV, lossless FLAC, or 320 kbps MP3) and render the enhanced copy.
  4. 4Review the measured output report detailing integrated loudness, true-peak levels, noise floor reduction in decibels, and the reproducible FFmpeg filter chain.

Use cases

  • Forensic audio examiners generating defensible, documented derivatives of noisy witness recordings for courtroom presentation.
  • Transcriptionists and researchers isolating dialogue from high-noise field interviews to boost automatic transcription accuracy.
  • Investigative journalists cleaning up noisy archival wiretaps or field recordings using standard speech frequency cutoffs.

Examples

1. Enhancing Noisy Witness Interview Audio

Forensic Audio Analyst

Background

An investigator received an interview recording with heavy HVAC hum and fluctuating vocal levels that made quiet statements difficult to hear.

Problem

The analyst needed to improve vocal intelligibility while maintaining an audit trail showing exactly how the audio was filtered.

How to use

Upload the original audio file, select the 'Evidence clarity' preset at 'standard' strength, choose 'WAV 24-bit PCM' output, and export.

Preset: evidence-clarity | Strength: standard | Output: wav-24

Outcome

A 24-bit PCM WAV derivative with roughly 9 dB lower pause noise floor, smoothed voice levels via gentle 2:1 leveling, and an exportable filter log for court disclosure.

2. Conditioning Field Audio for Automated Speech-to-Text

Transcription Technician

Background

A legal transcriptionist has hours of deposition audio captured in a room with traffic rumble, causing repeated dropped words in automated transcription engines.

Problem

Speech-to-text models require consistent signal levels and minimal pause noise rather than warm, natural room acoustics.

How to use

Upload the recording, select the 'Transcription prep' preset at 'strong' strength, pick 'FLAC (lossless)', and process.

Preset: transcription-prep | Strength: strong | Output: flac

Outcome

A clean FLAC file with aggressive FFT denoising and gating between speech pauses, significantly reducing hallucinated words and transcription dropouts.

3. Band-Limiting Archival Wiretap Recording

Investigative Journalist

Background

A media outlet received an old, distorted telephone recording containing high-frequency hiss and low-frequency electrical hum.

Problem

The dialogue was buried beneath wideband noise outside the human speech frequency band.

How to use

Upload the audio file, select the 'Telephone band' preset at 'standard' strength, choose 'MP3 320 kbps', and download the review copy.

Preset: telephone-band | Strength: standard | Output: mp3-320

Outcome

A 320 kbps MP3 derivative band-limited strictly to 300–3400 Hz with background pauses gated out, isolating the intelligible vocal dialogue.

FAQ

Does this tool alter or overwrite my original audio file?

No. The original file is never modified; enhancements are rendered strictly to a separate derivative copy.

How is the filter chain documented for legal disclosures?

The verbatim FFmpeg filter chain string, parameters, and before-and-after loudness metrics are included directly in the processing metadata report.

What is the difference between Evidence clarity and Transcription prep?

Evidence clarity preserves the full audible speech band with conservative denoising and leveling, while Transcription prep applies aggressive gating and denoising tuned for automated speech-to-text engines.

What audio export formats are supported?

You can export the enhanced derivative as 24-bit PCM WAV, lossless FLAC, or 320 kbps MP3.

How is the noise floor reduction calculated?

The analyzer measures input and output levels across the quietest 10 percent of 100 ms blocks using BS.1770-4 integrated loudness and true-peak metering.

Related

Continue with connected tools and hubs

Cookie settings

Essential cookies keep the site running. Analytics and personalized ads are optional.

Cookie policy