Start using

CALM Act Commercial Loudness Checker

Read more

Check whether a commercial is louder than the programme it accompanies, per the FCC CALM Act rules and ATSC A/85: compare average loudness, grade the excess on the A/85 listener comfort scale, and flag loud-opening “gaming” with momentary-loudness diagnostics.

Inputs

Current media limits

Current plan: —

audio
—
Checking your current limits

Result

Ready for a run

Run the tool to preview files, text, structured data, or streamed output here.

Examples

2 examples

Choose an example to fill in the form.

  • A 30-second spot measured at exactly -24.0 LKFS against a programme anchor measured at -24.0 LKFS: the loudness difference is 0.0 dB, comfortably inside the A/85 comfort zone, and the true peak stays under the -2.0 dBTP limit.

    Green compliant hero with a 0.0 dB loudness difference, the comfort-zone ruler pinned at 0, both measurement cards at -24.0 LKFS and no findings

  • Using the manual anchor mode with the A/85 -24 LKFS anchor, a commercial delivered at -20.0 LKFS reads +4.0 dB over the programme: outside the ±2 dB A/85 tolerance, graded perceptibly louder on the Annex E scale — the exact exposure the CALM Act was written to stop.

    Red hero with +4.0 dB loudness difference, severity perceptibly-louder, the comfort-zone ruler pinned past the +2.4 dB comfort edge but before the +5.6 dB turn-volume-down point

Last updated

Details

What this tool helps you do

The US CALM Act (enacted 15 December 2010, FCC rules effective 13 December 2012) requires TV commercials to be transmitted no louder than the programme material they accompany; the FCC rules incorporate ATSC A/85 by reference, whose core requirement is that the average loudness of a commercial must not exceed the average loudness of the surrounding programming. This checker measures both files the way the standard does: ITU-R BS.1770-4 K-weighted integrated loudness with the two-stage EBU Mode gate, taken over the full duration including all channels except LFE (A/85 Annex J.4). For long-form programmes A/85 anchors on the dialogue element; this tool measures the full-program mix, so for cinematic mixes you can instead enter the known anchor or dialnorm value directly. The loudness difference is graded on the A/85 Annex E listener tolerance scale: +2.4 dB is louder-but-acceptable, +5.6 dB makes viewers reach for the volume control, +10.8 dB is annoyingly loud, while a commercial up to +2 dB over the programme sits inside the A/85 measurement tolerance. True peak of the commercial is checked against the A/85 −2.0 dBTP limit, and because the FCC’s 2025 review highlights commercials that “game” the average with an exceptionally loud opening, the maximum momentary (400 ms) loudness of the commercial is compared with the programme’s as an informational diagnostic. Files are only read, never modified.

Tool usage guide

Learn when to use this tool, what it supports, and how real users apply it.

Key facts

Category
Media
Input types
File, Select, Number
Output type
html
Sample coverage
4
API ready
Yes

Overview

The CALM Act Commercial Loudness Checker evaluates TV and broadcast advertising audio against FCC CALM Act mandates and ATSC A/85 standards to ensure commercials do not overpower accompanying programming.

When to use

  • Before delivering commercial audio spots to US broadcast stations or cable networks.
  • During quality control to verify true peak limits and ITU-R BS.1770-4 integrated loudness compliance.
  • When diagnosing listener comfort scale excess or potential loud-opening average gaming.

How it works

  1. 1Upload the commercial audio file and provide the accompanying programme audio file or enter a known programme anchor loudness in LKFS.
  2. 2The tool calculates the ITU-R BS.1770-4 K-weighted integrated loudness using EBU Mode gating across all channels except LFE.
  3. 3It measures the maximum true peak against the ATSC A/85 -2.0 dBTP limit and compares momentary loudness to identify abrupt spikes.
  4. 4A compliance report generates a loudness difference metric, Annex E comfort scale rating, and true peak verification.

Use cases

  • Broadcast delivery verification for agency audio mixers preparing 30-second broadcast spots.
  • Network ingestion QC to prevent FCC rule violations across sponsor ad reels.
  • Comparative loudness analysis for dynamic commercial intros against television programme dialogue anchors.

Examples

1. Standard Broadcast Commercial Quality Assurance

Broadcast Audio Engineer

Background

An agency is delivering a 30-second campaign spot to a national US television network with a strict -24.0 LKFS dialnorm requirement.

Problem

The engineer must confirm that the commercial matches the target anchor level and adheres to true peak restrictions.

How to use

Set the programme source to manual with a -24.0 LKFS anchor, then upload the mixed commercial WAV file.

Program Source: Manual
Programme Anchor Loudness: -24.0 LKFS
Commercial Audio: commercial_mix_v1.wav

Outcome

The report confirms an integrated loudness of -24.0 LKFS (0.0 dB delta) and a -2.3 dBTP peak, confirming full CALM Act compliance.

2. Commercial vs Programme Mix Validation

Post-Production Supervisor

Background

A syndicated show contains episodic dynamic audio and custom station commercial interstitials.

Problem

Viewers may experience jarring volume spikes if the commercial mix exceeds the integrated loudness of the accompanying segment.

How to use

Upload both the show segment audio and the commercial audio into the checker to measure full integrated and momentary differences.

Program Source: Upload
Programme Audio: episode_act1.wav
Commercial Audio: promo_spot.wav

Outcome

The tool identifies a +4.0 dB discrepancy, flagging the commercial on the Annex E listener tolerance scale as perceptibly louder.

FAQ

What standard does this checker use for loudness calculation?

It uses ITU-R BS.1770-4 K-weighted integrated loudness with two-stage EBU Mode gating, adhering to ATSC A/85 Annex J.4.

What is the maximum allowed true peak under ATSC A/85?

ATSC A/85 establishes a true peak ceiling of -2.0 dBTP for commercial content.

Can I check a commercial without uploading the full programme file?

Yes, switch the programme source option to manual and input your dialnorm or target anchor value in LKFS.

Does this tool alter or re-encode my source audio files?

No, files are processed strictly in read-only mode to measure acoustic parameters without modifying the audio data.

What is considered an acceptable loudness difference between commercial and programme?

A commercial sitting within +2.0 dB of the programme anchor falls inside standard ATSC A/85 measurement tolerance.

Related

Continue with connected tools and hubs

Cookie settings

Essential cookies keep the site running. Analytics and personalized ads are optional.

Cookie policy