Elysia Tools Docs
EN
Language
ZHESPTRUFRDEEN
Back to site

© 2026 Elysia Tools. Developer documentation.

Back to siteBrowse tools
All categoriesImages, Audio & VideoMath, Date & FinanceDesign & ColorText & WritingDeveloper & WebConversion & EncodingData & TablesDocuments & PDFSecurity & ValidationCharts & Visualization
644 tools in Math, Date & Finance

ISO 8601 Converter

text

Date & Time

Convert dates to and from ISO 8601 format

iso-8601-converter

Integral Calculator

text

Math & Numbers

Calculate indefinite integrals of common functions

integral-calculator

Inflation Calculator

json

Finance

Calculate the effect of inflation on purchasing power and future value of money

inflation-calculator

Hebrew / Jewish Calendar Bilingual Date Converter

html

Date & Time

Converts any date between Gregorian, Julian and the fixed Hebrew calendar: molad of the month, the four dehiyyot postponement judgments, keviyah year type, the weekly Torah portion (parasha) for Israel or Diaspora, the Omer count, the full festival schedule of the Hebrew year and the Anno Mundi era in Hebrew letters.

hebrew-calendar-bilingual-date-converter

Heat Transfer Coefficient Converter (W/(m²·K) ↔ kcal)

json

Math & Numbers

Convert convective heat transfer coefficient (film coefficient h) between W/(m²·K) (watt per square metre-kelvin, SI base, = W/(m²·°C)) and kcal/(m²·h·°C) (1 = 1.1627778 W/(m²·K)). Converts via W/(m²·K) and lists both equivalents. h depends on flow regime and surface, not material. Typical ranges: natural-convection air ≈ 5–25, forced air ≈ 25–250, still water ≈ 100–1000, boiling/condensing water ≈ 2500–50000+ W/(m²·K).

heat-transfer-coefficient-converter

Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)

json

Math & Numbers

Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.

heat-exchanger-ntu

Heating Load Calculator (Envelope Transmission + Infiltration)

json

Math & Numbers

Estimate the heating (heat-loss) load of a room by the simplified steady-state method. Envelope transmission loss Q_trans = Σ(A_i·U_i·ΔT) over surfaces entered one per line as 'area,U' (U in W/(m²·K)). Cold-air infiltration loss Q_inf = 0.018·ACH·V·ΔT (W), where 0.018 W·h/(m³·K) ≈ ρ·c_p/3600. Total load = Q_trans + Q_inf, optionally multiplied by a safety factor (default 1.0). ΔT = indoor - outdoor (heating, >0). Temperature in °C/K/°F (only differences matter), area in m²/ft².

heating-load-calculator

Heat Conduction Calculator (Fourier's Law, q=kΔT/d)

json

Math & Numbers

Compute 1-D steady-state heat conduction through a flat slab (Fourier's law): heat flux q = k·ΔT/d (W/m²), heat flow rate Q = k·A·ΔT/d (W), and thermal resistance R = d/(k·A) (K/W). k is the thermal conductivity (W/(m·K)); ΔT is the temperature difference (K; a °C difference equals a K difference, a °F difference is converted by ×5/9); d the slab thickness; A the cross-section area. ΔT may be negative (indicating reverse heat flow), but k, d and A must be positive. Thickness in m/cm/mm, area in m²/cm².

heat-conduction-calculator

Heat Convection Calculator (Newton's Law, q=hΔT)

json

Math & Numbers

Compute convective heat transfer (Newton's law of cooling): heat flux q = h·ΔT (W/m²), heat flow rate Q = h·A·ΔT (W), and convective thermal resistance R_conv = 1/(h·A) (K/W). h is the convective heat-transfer coefficient (W/(m²·K)); ΔT is the temperature difference between the surface and the fluid (K; a °C difference equals a K difference, a °F difference is converted by ×5/9); A the heat-transfer area. ΔT may be negative (indicating reverse heat flow), but h and A must be positive. Area in m²/cm².

heat-convection-calculator

Heat Exchanger LMTD Calculator (Log Mean Temperature Difference)

json

Math & Numbers

Compute the Log Mean Temperature Difference (LMTD) of a heat exchanger for parallel or counter flow. Parallel flow: ΔT₁ = T_h,in - T_c,in and ΔT₂ = T_h,out - T_c,out; counter flow: ΔT₁ = T_h,in - T_c,out and ΔT₂ = T_h,out - T_c,in. LMTD = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂), or ΔT₁ when ΔT₁ = ΔT₂. A non-positive terminal difference (temperature cross) is physically impossible and is rejected. Optionally, with the overall heat transfer coefficient U (W/(m²·K)) and the heat transfer area A (m²), the heat transfer rate Q = U·A·LMTD (W) is returned. Temperatures are used only as differences: Δ°C = ΔK and Δ°F ×5/9 = ΔK; the LMTD is reported in K.

heat-exchanger-lmtd

Heat Radiation Calculator (Stefan-Boltzmann Law, Q=εσA·T⁴)

json

Math & Numbers

Compute thermal radiation from a blackbody/grey body (Stefan-Boltzmann law): blackbody emissive power E_b = σ·T⁴ (W/m²), total radiated power Q_rad = ε·σ·A·T⁴ (W); with an optional surrounding temperature T₀ it also computes the net radiative exchange Q_net = ε·σ·A·(T⁴-T₀⁴) (W). σ = 5.670374419e-8 W/(m²·K⁴); ε is the emissivity (0 < ε ≤ 1, blackbody ε=1); T is the ABSOLUTE temperature (K) — °C and °F are first converted to K (this is an absolute temperature, not a difference); A is the radiating area. Area in m²/cm².

heat-radiation-calculator

HP to KW

json

Math & Numbers

Convert horsepower to kilowatts with configurable decimal precision

hp-to-kw
Previous
33
34
35
36
37
38
39
Next