Heat Exchanger ε-NTU Calculator (Effectiveness-NTU Method)

Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.

json· JSON resultOpen tool

Quick start

Call this tool from your code in three languages.

cURL
curl -X POST 'https://api.elysiatools.com/en/api/tools/heat-exchanger-ntu' \
  -H 'Content-Type: application/json' \
  -d '{"exchangerType":"counter","hotCapacityRate":1000,"coldCapacityRate":1500,"overallU":500,"area":10,"hotInletTemp":0,"coldInletTemp":0,"tempUnit":"°C","decimalPlaces":4}'

API reference

Send a POST request with your inputs as JSON. File parameters require a separate upload first.

Endpoint

HTTP
POST https://api.elysiatools.com/en/api/tools/heat-exchanger-ntu

Parameters

NameTypeRequiredDescription
exchangerTypeselectNoExchanger arrangement: Parallel Flow, Counter Flow, Shell-and-Tube (1 shell pass / 2 tube passes), or Crossflow (single pass, both fluids unmixed).
hotCapacityRatenumberYesHot-side heat-capacity rate C_h = ṁ_h·c_p,h in W/K.
coldCapacityRatenumberYesCold-side heat-capacity rate C_c = ṁ_c·c_p,c in W/K.
overallUnumberYesOverall heat transfer coefficient U in W/(m²·K).
areanumber

MCP integration

Add this tool to your Model Context Protocol server so AI agents can list and call it.

Server configuration

Add this block to your MCP client configuration:

mcp.json
{
  "mcpServers": {
    "elysiatools-heat-exchanger-ntu": {
      "name": "heat-exchanger-ntu",
      "description": "Compute the effectiveness (ε) of a heat exchanger by the ε-NTU method. C*=C_min/C_max (0..1), NTU=U·A/C_min, q_max=C_min·(T_h,in-T_c,in), and ε=q_actual/q_max. Supports four arrangements: Parallel flow ε=[1-exp(-NTU(1+C*))]/(1+C*); Counter flow ε=[1-exp(-NTU(1-C*))]/[1-C*·exp(-NTU(1-C*))], or NTU/(1+NTU) when C*=1; Shell-and-tube 1-2 ε=2/[1+C*+√(1+C*²)·(1+exp(-NTU√(1+C*²)))/(1-exp(-NTU√(1+C*²)))]; Crossflow (both unmixed) ε=1-exp{(NTU^0.22/C*)·[exp(-C*·NTU^0.78)-1]}. When C*=0 (phase change on one side, boiler/condenser) every arrangement gives ε=1-exp(-NTU). Optionally supply T_h,in and T_c,in to recover the actual heat-transfer rate q=ε·q_max and both outlet temperatures. Temperatures are used only as differences: Δ°C=ΔK and Δ°F×5/9=ΔK.",
      "baseUrl": "https://api.elysiatools.com/mcp/sse?toolId=heat-exchanger-ntu",
      "command": "",
      "args": [],
      "env": {},
      "isActive": true,
      "type": "sse"
    }
  }
}

List available tools

After connecting to the SSE endpoint, list the exposed tools:

tools/list
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/list"
}

Call this tool

Invoke the tool by its id, passing arguments built from its parameters:

tools/call
{
  "jsonrpc": "2.0",
  "id": 2,
  "method": "tools/call",
  "params": {
    "name": "heat-exchanger-ntu",
    "arguments": {
  "exchangerType": "counter",
  "hotCapacityRate": 1000,
  "coldCapacityRate": 1500,
  "overallU": 500,
  "area": 10,
  "hotInletTemp": 0,
  "coldInletTemp": 0,
  "tempUnit": "°C",
  "decimalPlaces": 4
}
  }
}
Browse toolsOpen tool

© 2026 Elysia Tools. Developer documentation.

Back to siteBrowse tools
Yes
Heat transfer area A in m².
hotInletTempnumberNoHot-side inlet temperature T_h,in, in the selected Temperature Unit. Optional; when supplied together with T_c,in the actual heat-transfer rate and both outlet temperatures are returned.
coldInletTempnumberNoCold-side inlet temperature T_c,in, in the selected Temperature Unit. Optional; when supplied together with T_h,in the actual heat-transfer rate and both outlet temperatures are returned.
tempUnitselectNoUnit of the inlet temperatures. Only differences matter: Δ°C = ΔK and Δ°F ×5/9 = ΔK.
decimalPlacesnumberNo—

Response format

JSON result

JSON
{
  "key": {...},
  "metadata": {
    "key": "value"
  },
  "error": "Error message (optional)",
  "message": "Notification message (optional)"
}
Chain multiple tools in one session with a comma-separated toolId list, e.g. /mcp/sse?toolId=png-to-webp,jpg-to-webp,gif-to-webp (max 20).

Questions or issues? Contact [email protected]