1. 25% · charge
How to use
C-rate: 1 C; Simulated time: 900 s; Q = 2 Ah; SOC₀ = 25%.
Outcome
SOC = 50%; ΔQ = +0.5 Ah.
Elysia Tools
Navigation
Chemistry
Trace lithium-ion and electron paths, integrate ideal SOC in simulated time, and distinguish charge, energy and power without predicting cell aging or safety.
Open static visualizationAt a Glance

Verified Results
Every parameter set and result below is a fixed output of this page's built-in model (each asserted before delivery) and reproduces directly: set the Parameters column in the interactive panel.
| Scenario | Parameters | Result |
|---|---|---|
| Quarter-hour charge | Q = 2 Ah; I = +2 A; t = 900 s; SOC₀ = 25% | SOC = 50%; ΔQ = +0.5 Ah |
| Half-rate discharge | Q = 2 Ah; I = −1 A; t = 1800 s; SOC₀ = 75% | SOC = 50%; ΔQ = −0.5 Ah |
| Ideal empty time | Q = 2 Ah; I = −4 A; SOC₀ = 100% | t = 1800 s; SOC = 0% |
| Charge boundary | Q = 2 Ah; I = +2 A; t = 900 s; SOC₀ = 90% | SOC = 100%; t_active = 360 s; ΔQ = +0.2 Ah; ΔE = +0.72 Wh |
| Constant-voltage energy | V = 3.6 V; Q = 2 Ah; SOC = 50%; |I| = 2 A | E = 3.6 Wh; E_full = 7.2 Wh; P = 7.2 W |
| Consistent mass basis | m = 0.1 kg; E_full = 7.2 Wh; P = 7.2 W | E/m = 72 Wh/kg; P/m = 72 W/kg |
Sources
Papers and datasets underlying this visualization - every formula, algorithm, and data anchor on the page traces back to the sources below.
U.S. Department of Energy, Office of Science (2023). DOE Explains...Batteries. DOE Explains.
University of Washington, Clean Energy Institute. Lithium-Ion Battery.
Nick Richards (2023). Battery Gauging Algorithm Comparison. Texas Instruments, SLUAAR3, §§4, 7.1.
Related
Next
Penn State College of Earth and Mineral Sciences. Interpreting Battery Parameters and Specification Sheets. AE 868.
COMSOL. Lithium-Ion Battery Rate Capability. COMSOL 6.4 documentation.
Paul Flowers, Klaus Theopold, Richard Langley, William R. Robinson (2019). Chemistry 2e. OpenStax, §17.2 Galvanic Cells.
Tool usage guide
Ideal teaching model: fixed 2 Ah capacity, unit coulombic efficiency, illustrative constant 3.6 V and 0.1 kg mass. No CC–CV controller, diffusion, polarization, resistive losses, temperature response, aging or safety prediction.
Li⁺ crosses the electrolyte; electrons use the external circuit. The dots are symbolic flow cues, not a lithium inventory or transport calculation. Conventional current points opposite to electron transfer.
x is a schematic stoichiometric fraction, not the displayed SOC. The reverse reaction represents discharge; this is not a safe operating range.
Positive current charges; negative current discharges. SOC is clamped to its endpoints, with only accepted charge and energy counted. Repeated Start clicks retain one animation loop; pause excludes wall time.
ΔSOC = I Δt / (3600 Q); E = V Q_remaining; P = V |I|.
The voltage line stays at the illustrative 3.6 V. Remaining energy is V × remaining Ah; power magnitude is V × |I|. Real delivered energy requires integrating terminal voltage times discharge current over time.
The ideal point uses full energy divided by 0.1 kg and power divided by the same mass. Changing C-rate moves power, not available ideal energy. This is not a measured Ragone tradeoff or a ranking of battery chemistries.
Capacity is fixed here. No cycle-life curve or numerical retention prediction is calculated.
Real aging depends on cell chemistry, operating history and conditions. A chosen reporting threshold is not a universal physical failure boundary. Coulombic efficiency is charge out divided by charge in over a defined cycle, not a capacity-fade slope.
Short circuits, overcharge, heat and mechanical damage can create hazards. This panel does not compute temperatures, safe limits or protection success.
A BMS monitors and controls operation; separators and other protective components have specific failure limits. No checkbox can guarantee safety. Use cell and pack manufacturer documentation for actual operating limits.
What aging would require
Capacity is fixed here. No cycle-life curve or numerical retention prediction is calculated.
Mechanisms, not a safety test
Short circuits, overcharge, heat and mechanical damage can create hazards. This panel does not compute temperatures, safe limits or protection success.
Voltage is an assumption, not a fitted curve
The voltage line stays at the illustrative 3.6 V. Remaining energy is V × remaining Ah; power magnitude is V × |I|. Real delivered energy requires integrating terminal voltage times discharge current over time.
How to use
C-rate: 1 C; Simulated time: 900 s; Q = 2 Ah; SOC₀ = 25%.
Outcome
SOC = 50%; ΔQ = +0.5 Ah.
How to use
Q = 2 Ah; I = +2 A; t = 900 s; SOC₀ = 90%.
Outcome
SOC = 100%; t_active = 360 s; ΔQ = +0.2 Ah; ΔE = +0.72 Wh.
The ideal point uses full energy divided by 0.1 kg and power divided by the same mass. Changing C-rate moves power, not available ideal energy. This is not a measured Ragone tradeoff or a ranking of battery chemistries.
Ideal teaching model: fixed 2 Ah capacity, unit coulombic efficiency, illustrative constant 3.6 V and 0.1 kg mass. No CC–CV controller, diffusion, polarization, resistive losses, temperature response, aging or safety prediction.