# Thermal Conductivity Converter (W/(m·K) / kcal / BTU)

Convert thermal conductivity between W/(m·K) (watt per metre-kelvin, SI base, = W/(m·°C)), kcal/(m·h·°C) (1 = 1.1627778 W/(m·K)), and BTU/(hr·ft·°F) (1 = 1.7307347 W/(m·K)). Converts via W/(m·K) to the target unit and also lists the equivalent value in all three units for reference. Reference values: copper ≈ 401, aluminum ≈ 237, steel ≈ 50, water ≈ 0.6, air ≈ 0.026, insulation foam ≈ 0.03 W/(m·K).

> Canonical page: https://elysiatools.com/en/tools/thermal-conductivity-converter

- **Category:** Math & Numbers

- **Keywords:** thermal conductivity, conductivity conversion, W/(m·K), watt per metre kelvin, kcal/(m·h·°C), kilocalorie, BTU/(hr·ft·°F), BTU, heat transfer, insulation, heat conduction

## Overview

Convert non-negative thermal conductivity values between W/(m·K), kcal/(m·h·°C), and BTU/(hr·ft·°F). The tool converts through W/(m·K), returns the selected output unit, and lists equivalent values in all three units.

## Inputs

- **Input unit** (select)
- **Value** (number): Thermal conductivity in the selected Input unit. Must be non-negative.
- **Output unit** (select)
- **Decimal Places** (number)

## When to use

- Convert SI thermal conductivity values into kcal/(m·h·°C) or BTU/(hr·ft·°F).
- Translate material conductivity data between metric and imperial engineering units.
- Check reference values for conductors, water, air, or insulation materials.

## How it works

- Enter a non-negative thermal conductivity value.
- Select the input unit: W/(m·K), kcal/(m·h·°C), or BTU/(hr·ft·°F).
- Choose the output unit and set the number of decimal places from 0 to 10.
- The tool converts through W/(m·K) and returns the selected result plus equivalents in all three units as JSON.

## Use cases

- Compare thermal conductivity data from metric and imperial engineering references.
- Convert insulation, air, water, steel, aluminum, or copper reference values for calculations.
- Prepare consistently formatted conductivity values for heat-transfer and material-comparison work.

## Frequently asked questions

### Which thermal conductivity units are supported?

The tool supports W/(m·K), kcal/(m·h·°C), and BTU/(hr·ft·°F).

### What input values are accepted?

The value must be a non-negative number.

### What conversion factors are used?

1 kcal/(m·h·°C) equals 1.1627778 W/(m·K), and 1 BTU/(hr·ft·°F) equals 1.7307347 W/(m·K).

### Can I choose the displayed precision?

Yes. Set decimal places from 0 to 10; the default is 6.

### Does the result include other unit equivalents?

Yes. The JSON result includes the selected output and equivalent values in all three supported units.

## Related tools

- [Air Changes per Hour (ACH, n = Q/V)](https://elysiatools.com/en/tools/air-changes-per-hour): Compute the air change rate (ACH / n) of a room from the outdoor supply airflow Q and the room volume V: n = Q/V (1/h). Three modes: solve ACH (given Q and V), solve airflow (given n and V), or solve volume (given n and Q). Flow in m³/s/m³/h/CFM, volume in m³/ft³/L. Also reports the well-mixed single-zone purge time to reach a target residual fraction ε (default 1%): t = −ln(ε)/n hours.
- [Bar to PSI](https://elysiatools.com/en/tools/bar-to-psi): Convert bar to pounds per square inch with configurable decimal precision
- [Bearing Life L10 Calculator](https://elysiatools.com/en/tools/bearing-life-l10): Calculate the basic rating life of a rolling bearing: L10 = (C/P)^p, with p = 3 for ball bearings and p = 10/3 for roller bearings. When a speed is provided, converts to L10h in operating hours.
- [Bits to GB](https://elysiatools.com/en/tools/bits-to-gb): Convert bits to gigabytes with decimal vs binary interpretation, alternate-system comparison, and network-speed-aware transfer estimates
- [Bits to MB](https://elysiatools.com/en/tools/bits-to-mb): Convert bits to megabytes with decimal vs binary interpretation, alternate-system comparison, and network-speed-aware transfer estimates
- [Bolt Torque Clamp Force Calculator](https://elysiatools.com/en/tools/bolt-torque-clamp-force): Convert between bolt tightening torque and axial clamp force. T = K·F·d, where K is the nut factor (~0.20 for dry steel). Solve torque from force, or force from torque.
- [BTU to Joule](https://elysiatools.com/en/tools/btu-to-joule): Convert BTU to joules with configurable decimal precision
- [Bytes to GB](https://elysiatools.com/en/tools/byte-to-gb): Convert bytes to gigabytes with decimal vs binary interpretation, alternate-system comparison, and network-speed-aware transfer estimates

## Samples

- [Web Image Processing Python Samples](https://elysiatools.com/en/samples/web-image-processing-python): Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion
- [Android Image Processing Java Samples](https://elysiatools.com/en/samples/android-image-processing-java): Android Java image processing examples including reading/saving images, scaling, and format conversion
- [Android Image Processing Kotlin Samples](https://elysiatools.com/en/samples/android-image-processing-kotlin): Android Kotlin image processing examples including reading/saving images, scaling, and format conversion
- [Web Image Processing Rust Samples](https://elysiatools.com/en/samples/web-image-processing-rust): Web Rust image processing examples including image read/save, scaling, and format conversion

## Related content

- [HVAC Load, Airflow, Refrigeration, and Thermal Comfort Review](https://elysiatools.com/en/hubs/hvac-load-airflow-refrigeration-comfort): Estimate HVAC loads, airflow, psychrometric states, refrigeration conditions, heat-transfer effects, and thermal comfort for an engineering review.