# Seismic Scale Converter (JMA / MMI / Magnitude / Energy)

Convert earthquake magnitude to radiated energy in joules and TNT, reverse energy back to magnitude, and compare JMA shindo with MMI using approximate intensity equivalents. Magnitude and local shaking intensity are different quantities; the tool does not invent a shindo or MMI value from magnitude alone.

> Canonical page: https://elysiatools.com/en/tools/seismic-scale-converter

- **Category:** Science & Education

- **Keywords:** Seismic Scale Converter (JMA / MMI / Magnitude / Energy), earthquake, seismic, magnitude, JMA, shindo, MMI, 震度, 地震

## Overview

Uses the Gutenberg–Richter relation log10E = 4.8 + 1.5M (E in joules) or the USGS moment-magnitude approximation log10E = 5.24 + 1.44Mw. JMA 0–7 and MMI I–XII are mapped with the approximate equivalents published in JMA scale reference tables. Magnitude and energy describe the earthquake source; JMA intensity and MMI describe shaking at one location and also depend on depth, distance, path, and site conditions. The tool therefore labels cross-family outputs as not determined instead of presenting a false precise conversion. Includes a JMA/MMI reference table and TNT equivalents.

## Inputs

- **Input scale** (select)
- **Value** (text): 5.7, 2.24e13, 5+, or VII
- **Energy unit** (select)
- **Energy formula** (select)

## When to use

- Converting an earthquake magnitude into radiated energy in joules or TNT equivalent units.
- Estimating equivalent earthquake magnitude from a known quantity of radiated seismic energy.
- Looking up the approximate Modified Mercalli Intensity (MMI) equivalent for a reported JMA shindo level.

## How it works

- Select the measurement family from the Input scale dropdown: Magnitude (M), Energy, JMA intensity (shindo), or MMI (Mercalli).
- Type the numerical or categorical reading into the Value field (such as 5.7, 2.24e13, 5+, or VII).
- For magnitude and energy calculations, select the preferred unit under Energy unit (e.g., Joules (J), Kilotons TNT (kt), or Megatons TNT (Mt)) and choose between Gutenberg–Richter (generic M) or USGS (moment magnitude Mw) under Energy formula.
- Examine the output panel to read calculated energy and magnitude equivalents, or verify intensity scale mappings, noting that cross-family values between source magnitude and local shaking intensity remain undetermined.

## Use cases

- Seismic Energy Translation: Converting a reported M5.7 earthquake into joules and kilotons of TNT to illustrate total radiated energy in reports.
- Intensity Cross-Referencing: Mapping an observed Japanese shaking level of JMA 5+ to an approximate MMI band to help international teams understand local report severities.
- Energy-to-Magnitude Back-Calculation: Entering an energy value in petajoules or megatons of TNT to find the corresponding seismic magnitude on the USGS Mw scale.

## Frequently asked questions

### Why does the converter not output a JMA shindo or MMI value when given a magnitude?

Magnitude measures total energy released at the source, whereas JMA and MMI measure local shaking at a specific site. Shaking depends heavily on distance, focal depth, and soil conditions, so direct conversion without site parameters is physically invalid.

### What is the difference between the Gutenberg–Richter and USGS Mw formulas?

Gutenberg–Richter (log10E = 4.8 + 1.5M) is the traditional empirical relation for generic magnitude, while the USGS formula (log10E = 5.24 + 1.44Mw) is calibrated specifically for moment magnitude.

### How are JMA shindo and MMI values compared?

They are aligned using empirical reference tables published by the Japan Meteorological Agency, providing an approximate qualitative equivalence rather than a continuous mathematical formula.

### Which energy units are supported?

You can select Joules (J), metric multiples from kilojoules (kJ) up to exajoules (EJ), and TNT explosive yield equivalents in kilotons (kt) or megatons (Mt).

### How should Mercalli intensity inputs be formatted?

Enter standard Roman numerals from I through XII in the Value field when MMI (Mercalli) is selected as the input scale.

## Related tools

- [Mosquito-borne Disease Basic Reproduction Number R0 Tutor](https://elysiatools.com/en/tools/mosquito-borne-disease-basic-reproduction-r0-tutor): Ross–Macdonald R0 = m·a²·b·c·pⁿ/(−r·ln p) for malaria, dengue, Zika or chikungunya: herd-immunity threshold, vectorial capacity, critical mosquito density, parameter elasticities, control targets and a seasonal transmission-window curve.
- [Physics Kinematics Problem Solver](https://elysiatools.com/en/tools/physics-kinematics-problem-solver): Solve 1D constant-acceleration kinematics problems and 2D projectile motion, with a full step-by-step derivation. Enter any 3 of the 5 quantities (displacement, initial velocity, final velocity, acceleration, time) and the solver finds the other two, showing each formula, the substitution, and the result. For projectiles, enter launch speed/angle/height to get range, time of flight, and max height.
- [Shapiro-Wilk, Anderson-Darling and Lilliefors Normality Tutor](https://elysiatools.com/en/tools/shapiro-wilk-anderson-darling-lilliefors-normality-tutor): Run the three workhorse normality tests (Shapiro-Wilk AS R94, Anderson-Darling, Lilliefors) with a Q-Q plot and a Monte-Carlo power comparison.
- [Arrhenius Equation Calculator](https://elysiatools.com/en/tools/arrhenius-equation-calculator): k = A·e^(−Ea/RT) solved for k, A, or Ea (two-point form), with Ea in kJ/mol and kcal/mol.
- [Battery Capacity Calculator](https://elysiatools.com/en/tools/battery-capacity-calculator): C = I·t both ways — runtime from capacity or capacity from runtime — with optional voltage for Wh and W.
- [Beer-Lambert Law Calculator](https://elysiatools.com/en/tools/beer-lambert-law-calculator): A = ε·c·l both ways, with T = 10⁻ᴬ, %T, unit selectors, and the 0.05–1.0 working-range check.
- [Boiling Point Elevation](https://elysiatools.com/en/tools/boiling-point-elevation): ΔT_b = K_b·m·i from a solvent preset table with van't Hoff factor support and custom solvents.
- [Parallel-Plate Capacitance Calculator](https://elysiatools.com/en/tools/capacitance-calculator-parallel-plate): C = εᵣ·ε₀·A/d with area or square-side input, dielectric permittivity, and auto-scaled output from fF to µF.

## Samples

- [Web Image Processing Python Samples](https://elysiatools.com/en/samples/web-image-processing-python): Web Python image processing examples using PIL/Pillow including reading, saving, resizing, and format conversion
- [Android Image Processing Java Samples](https://elysiatools.com/en/samples/android-image-processing-java): Android Java image processing examples including reading/saving images, scaling, and format conversion
- [Android Image Processing Kotlin Samples](https://elysiatools.com/en/samples/android-image-processing-kotlin): Android Kotlin image processing examples including reading/saving images, scaling, and format conversion
- [Web Image Processing Rust Samples](https://elysiatools.com/en/samples/web-image-processing-rust): Web Rust image processing examples including image read/save, scaling, and format conversion
